Home  

 

 

 

 

 

 

  NeuroScan  

 

 

DuetSystem

 

  |    NEUROSCAN     |    EMG / PE    |    IOM    |    CPAP    |    HOLTER    |    QST    |    ESTIMULADORES    |    MONITOR    |

 

Home  Home   Telefone   + 55 11 3662-0762    Fax   + 55 11 3825-7311   E-mail   biolink@biolinkbr.com    E-mail   biolinksp@gmail.com

    : Quienes somos
 
    : : NEUROSCAN
     •Compumedics
    • EEG en fMRI
    • PE en fMRI
    • EEG PE Research
    • ESI
    • MAGLINK
    • NuAmps
    • SCAN 4.3
    • SCAN NuAmps Ex
    • Stim
    • Stim2
    • SynAmps
    • SynAmps2
    • TOOLBOX2003
    • Curry 5.0
    • Source 2.0
    • EEG alta Densidad
   EMG Electromiografía
    • Electromiografo
    • EMG Nicolet
    • EMG Synergy
    • EMG Medelec
    • EMG Cuantitativa
    • PEM
    • Potenciales
     Evocados
    • PE Visual
    • PE Auditivo
    • PE Somato
     Accessorios
   Electromiografia
    • Agujas EMG
    • Agujas
    Concéntricas
    • Agujas Monopolar
    • Aguja para Botox
    • Aguja Neurolisis
    • Agujas
    Subdermales
    • Barras de Estímulo
    • Electrodos Anillo
    : : IOM
    • Monitoreo
    Intraoperatorio
    • Monitoreo
    Intraquirúrgico
    : : Accesorios IOM
    • Cork Screw
    • Agujas
     Subdermales
    • Descartables
    Adhesivos
   Electroencefalógrafo
   Electroecefalografo
    • EEG Digital
    • EEG Ambulatorial
    • Ambulatrory EEG
    • Vídeo  EEG Digital
    • VEEG Cuantitativo
    • EEG con PSG
    • Polisomnografía
    • Sueño
    • PSG Ambulatorial
    • Corticografia y
   
EEG   
   Electrocorticografía
    • Corticografia
    : : TCD
    • Doppler
    Transcraneal
   Accesorios de EEG
    • Electrodos de EEG
    • Electrodo de EEG
    • Pediátrico
    • Adulto
    • Copitas doradas
    • Pasta conductora
    : : Accesorios
     Sueño
     Polisomnografia
    • Cintas Torácicas
    Cintas Abdominales
    • Cinta Respiratoria
    • Termistor nasal
    • Termistores
    • Nasobucales
    • Repiratorios
    • Cánula Repiratoria
    • Sensor Oximetría
    • Sensor Spo2
    • Sensor Oximetro
    • Microfono
    • Sleep Glossary
    • Glosario de Sueño
    • Glosario PSG
    : : Holter
    • Holter EEG
    • Holter de PSG
    • Holter de EEG
    • Holter de EKG
    • Holter  ECG
    Grabadores de ECG
    • Somté
    : : Monitor
    • Monitor de EEG
    en UTI
    • Pediatric Monitor
    • Brain  Monitor
    • Sleep  Monitor
    : : Monitores      Multiparamétricos
    • Multiparámetros
    • Monitores
    • PCO2
    • Capnografia
    : : Estimuladores
    • Digitimer
    • Cortical Stimulator
    • Digitimer D185
    • Estimulación
    • Estimulador
     Magnético
    • Magnetic
    Stimulator
  Neurolocalizadores
    • Neurolocalizador
    • Neuromonitor
    • TOF
    • Tren de 4
    • Neurostimulator
    • Neurostimulators
    • Neuroestimulator
    : : DuetSystem
    : : Medoc
    • Patway
    • TSA-II
    • GSA
    • VSA-3000
    • Diabetes
    • Dolor Crónico
    • FSD
    • Enf. de Hansen
    : : ThermalStim
    • Quantitative QST
    • Sensory QST
    • Testing QST
    • Hanseniasis
    • Hansen Disease
    : : Biofeedback
    • EMG
    • Electromiografía
    : : Synergy
    • Medelec Synergy
    EMG / EP
    • Medelec Synergy
    N2 EMG
    • Medelec Synergy
    EMG P
E
    • TECA Synergy
    • Reader Station
    • TECA
    •  Synergy  Server
    : : Nicolet Viking
    • VikingQuest IOM
    • VikingQuest
    • Protable EMG
    • VikingSelect
    • VikingSelect  IOM
    • Endeavor IOM
    : : Nicolet NicOne
    • Nicolet vEEG v32
    • Nicolet One
    • Ambulatory EEG
    • cEEG Module
    • nEEG Module
    • LTM Module
    • Monitor nICU
    • Nicolet One
    • Sleep  Monitor
    • Nic Vue
    • NicoletOne
    • LTM Module
    • NicoletOne Sleeo
    : TECA Disposable
    • Concentric EMG
    • Needle Electrodes
    • Monopolar
    • MyoJect
    • Needle Electrodes
    • TECA Disposable
    : : Región
    • Argentina
    • Brasil
    • Colombia
    • Chile
    • Buenos Aires
    • San Pablo
    : : Otros Links
    • Biolink
    • Biolink1
    • Biolink2
    • Biolink3
    • Biolink4
    • Biolink5
    • Biolink6
    • Biolink7
    • Biolink8
    • Biolink9

Estimulador Cortical D185 Cortical Stimulator


D185 MultiPulse Cortical Stimulator

Now used worldwide as an effective tool for intraoperative monitoring of the spinal cord, the D185 is the ONLY standalone stimulator with FDA clearance for this application.  The D185 allows transcranial motor evoked potentials (MEPs) to be used in surgical procedures such as scoliosis correction, spinal tumour resection and thoraco-abdominal aortic aneurysm (TAAA) repair.  The 1000V power source means that MEPs can even be evoked in patients with pre-existing neuropathologies.  Recent design enhancements facilitate (external) control of the trigger settings, making it easier to interface the D185 with various EMG systems.  In addition, customer feedback has prompted the inclusion of an added polarity reversal feature. Estimulador Cortical.

  

Alternative Application:  The brief high voltage output also makes the D185 suitable for nerve root stimulation during differential diagnosis of peripheral nerve disorders such as multifocal motor neuropathy and motor neuron disease.  Please refer to the Peripheral Stimulators section for further details on this application.Estimulador Cortical.

  

Major Features do estimulador cortical Include:


- 1000V maximum voltage output (set by user).

- 1.5A maximum current output (LCD monitor).

- Risetime of 0.1A per microsecond.

- 50µs pulse duration.

- 1 to 9 pulses with user defined interpulse interval.

- NEW Reversible output polarity switch.

- User defined trigger facilities permit integration with popular EMG recording equipment.


D185 MultiPulse Accessories

The D185 MultiPulse Cortical Stimulator can be supplied with a range of accessories to facilitate integration with your current operating theatre equipment and stimulation preferences.  The current range includes electrode extension leads, stimulator output plugs, a footswitch and a range of electrode connection head boxes.  Accessories can be viewed on the downloadable PDF (below). Estimulador Cortical.

 

 

D185-HB1 Electrode connection headbox (5m cable), pictured above.  This extension headbox provides 5 linked pairs of 1.5mm DIN sockets for connection to MEP electrodes closer to the site of stimulation.
D185-HB3 Electrode connection headbox with stimulus reversal and SEP electrode disconnection (inc. D185-CB1) - 5m.  Ideal for those using SEP monitoring who want to avoid saturating their SEP amplifier during MEP stimulation.
D185-HB4 Electrode extension cable - 5m.  Straight forward extension of the output sockets of the D185, terminating in a moulded pair of 1.5mm DIN sockets.
D185-TC1 Trigger cable (BNC - 3.5mm) - 1.5m.  For connection between your EP system and the D185.
D185-TC2 Trigger cable (BNC - SMB) - 1.5m.  For connection between your EP system and the D185.
D185-TC3 Trigger cable (BNC - BNC) - 1m.  For connection between your EP system and the D185.
D185-TC4 Trigger polarity inverter.  For connection between your EP system and the D185.
D185-TC5 Trigger cable (BNC socket - 3.5mm) - 0.6m.  For connection between your EP system and the D185.
D185-FS1 Foot switch to IP68.  Allows foot switch control of the D185.
D185-OC1 Output connector plugs for user assembly (pair).  Also suitable for use with the DS7A peripheral nerve/muscle stimulator.
D185-OL1 Output lead - moulded connector on 5m cable for user assembly.  Also suitable for use with the DS7A peripheral nerve/muscle stimulator.