Home  

 

 

 

 

 

 

  NeuroScan  

 

 

DuetSystem

 

  |    NEUROSCAN     |    EMG / PE    |    IOM    |    CPAP    |    HOLTER    |    QST    |    ESTIMULADORES    |    MONITOR    |

 

Home  Home   Telefone   + 55 11 3662-0762    Fax   + 55 11 3825-7311   E-mail   biolink@biolinkbr.com    E-mail   biolinksp@gmail.com

    : Quienes somos
 
    : : NEUROSCAN
     •Compumedics
    • EEG en fMRI
    • PE en fMRI
    • EEG PE Research
    • ESI
    • MAGLINK
    • NuAmps
    • SCAN 4.3
    • SCAN NuAmps Ex
    • Stim
    • Stim2
    • SynAmps
    • SynAmps2
    • TOOLBOX2003
    • Curry 5.0
    • Source 2.0
    • EEG alta Densidad
   EMG Electromiografía
    • Electromiografo
    • EMG Nicolet
    • EMG Synergy
    • EMG Medelec
    • EMG Cuantitativa
    • PEM
    • Potenciales
     Evocados
    • PE Visual
    • PE Auditivo
    • PE Somato
     Accessorios
   Electromiografia
    • Agujas EMG
    • Agujas
    Concéntricas
    • Agujas Monopolar
    • Aguja para Botox
    • Aguja Neurolisis
    • Agujas
    Subdermales
    • Barras de Estímulo
    • Electrodos Anillo
    : : IOM
    • Monitoreo
    Intraoperatorio
    • Monitoreo
    Intraquirúrgico
    : : Accesorios IOM
    • Cork Screw
    • Agujas
     Subdermales
    • Descartables
    Adhesivos
   Electroencefalógrafo
   Electroecefalografo
    • EEG Digital
    • EEG Ambulatorial
    • Ambulatrory EEG
    • Vídeo  EEG Digital
    • VEEG Cuantitativo
    • EEG con PSG
    • Polisomnografía
    • Sueño
    • PSG Ambulatorial
    • Corticografia y
   
EEG   
   Electrocorticografía
    • Corticografia
    : : TCD
    • Doppler
    Transcraneal
   Accesorios de EEG
    • Electrodos de EEG
    • Electrodo de EEG
    • Pediátrico
    • Adulto
    • Copitas doradas
    • Pasta conductora
    : : Accesorios
     Sueño
     Polisomnografia
    • Cintas Torácicas
    Cintas Abdominales
    • Cinta Respiratoria
    • Termistor nasal
    • Termistores
    • Nasobucales
    • Repiratorios
    • Cánula Repiratoria
    • Sensor Oximetría
    • Sensor Spo2
    • Sensor Oximetro
    • Microfono
    • Sleep Glossary
    • Glosario de Sueño
    • Glosario PSG
    : : Holter
    • Holter EEG
    • Holter de PSG
    • Holter de EEG
    • Holter de EKG
    • Holter  ECG
    Grabadores de ECG
    • Somté
    : : Monitor
    • Monitor de EEG
    en UTI
    • Pediatric Monitor
    • Brain  Monitor
    • Sleep  Monitor
    : : Monitores      Multiparamétricos
    • Multiparámetros
    • Monitores
    • PCO2
    • Capnografia
    : : Estimuladores
    • Digitimer
    • Cortical Stimulator
    • Digitimer D185
    • Estimulación
    • Estimulador
     Magnético
    • Magnetic
    Stimulator
  Neurolocalizadores
    • Neurolocalizador
    • Neuromonitor
    • TOF
    • Tren de 4
    • Neurostimulator
    • Neurostimulators
    • Neuroestimulator
    : : DuetSystem
    : : Medoc
    • Patway
    • TSA-II
    • GSA
    • VSA-3000
    • Diabetes
    • Dolor Crónico
    • FSD
    • Enf. de Hansen
    : : ThermalStim
    • Quantitative QST
    • Sensory QST
    • Testing QST
    • Hanseniasis
    • Hansen Disease
    : : Biofeedback
    • EMG
    • Electromiografía
    : : Synergy
    • Medelec Synergy
    EMG / EP
    • Medelec Synergy
    N2 EMG
    • Medelec Synergy
    EMG P
E
    • TECA Synergy
    • Reader Station
    • TECA
    •  Synergy  Server
    : : Nicolet Viking
    • VikingQuest IOM
    • VikingQuest
    • Protable EMG
    • VikingSelect
    • VikingSelect  IOM
    • Endeavor IOM
    : : Nicolet NicOne
    • Nicolet vEEG v32
    • Nicolet One
    • Ambulatory EEG
    • cEEG Module
    • nEEG Module
    • LTM Module
    • Monitor nICU
    • Nicolet One
    • Sleep  Monitor
    • Nic Vue
    • NicoletOne
    • LTM Module
    • NicoletOne Sleeo
    : TECA Disposable
    • Concentric EMG
    • Needle Electrodes
    • Monopolar
    • MyoJect
    • Needle Electrodes
    • TECA Disposable
    : : Región
    • Argentina
    • Brasil
    • Colombia
    • Chile
    • Buenos Aires
    • San Pablo
    : : Otros Links
    • Biolink
    • Biolink1
    • Biolink2
    • Biolink3
    • Biolink4
    • Biolink5
    • Biolink6
    • Biolink7
    • Biolink8
    • Biolink9

Estimulador Magnético - Magnetic Stimulator - EMG Motor EP

 

Neuro-MS

magnetic stimulator for diagnostic and therapeutic stimulation of cerebral cortex motor zones and peripheral nervous system



Neuro-MS General Properties

  • Built-in control unit with the convenient keyboard
  • Digital indicators displaying all the parameters of the magnetic stimulator operation
  • Connector for synchronization with the external devices
  • Computer connection via USB-port
  • “Delayed charging” mode
  • Multistage system of device protection
  • Three different coils in the delivery set

Applications in Diagnostics and Treatment:

  • Neurology
  • Epileptology
  • Traumatology and orthopedy
  • Pediatrics neurology
  • Pulmonology
  • Ophthalmology

Neuro-MS Features

Operation Convenience
Increased noise immunity allows to combine both the power part and high-accuracy electronics of control unit in one case.
Convenient keyboard allows to control all the parameters of the magnetic stimulation if the device operates in the autonomous mode.
Digital indicators display all the parameters of the stimulator operation.
Indicator of coil temperature.

   
 

Multistage Protection System


Protection from the coil overheating.
Protection of power circuits from the charges emerging in them at incomplete connection of coil connector.
Protection from the overheating in internal circuits.

Stimulation Capacities


Three coils allow to achieve the different intensity and impact depth in dependence on study or treatment purpose.

Device Operation with Any Neurophysiological Equipment


Possibility of stimulator connection to computer USB connector for the joint operation with digital EMG systems manufactured by Neurosoft Ltd.
Possibility of operation with EMG systems produced by third-party manufacturers supporting the operation with external stimulators and using “Start” input signal and (or) “Synchronization” output signal (“SYNCR.” slot) for this.
The connection of any EMG system to electrical stimulator output is possible.

Spheres of Applications

Principles of Magnetic Stimulation

The magnetic stimulator Neuro-MS uses magnetic pulses of short duration which can easily penetrate through clothes, cranium bones and soft tissues.

They exert influence upon deep peripheral nerves, cerebrum and spinal cord, which are inaccessible for other kinds of stimulation.

Treatment

Neurology — treatment of disorders and traumas of central and peripheral nervous system, including vascular and vertebragene pathologies, neuropathies, demyelinating diseases.

Traumatology and orthopedy — treatment of traumatic injury of bones, spinal column, muscles, joints, spine osteochondrosis and its complications.

Ophthalmology — use at partial atrophy of visual nerve as a result of any etiology.

Psychiatry — treatment of depressions, schizophrenia, obsessive-compulsive disorders, maniacal conditions and other psychiatric diseases.

Diagnostics

Ability of Neuro-MS magnetic stimulator to excite the motor zone of brain, zones of cervical and lumbar intumescences of spinal cord and all medullispinal roots easily and painlessly allows the doctor to assess the state of cerebral and spinal motor pathways of adults and children exactly.

Neurology:

  • Study of motor response at magnetic stimulation of peripheral nerves
  • Determination of central motor conduction time of patients suffering from demyelinating diseases of nervous system, in particular, multiple sclerosis
  • Assessment of excitability and flexibility of cortex motor zones
  • Assessment of root conduction time (F-wave and segmental magnetic stimulation) at osteochondrosis

Epileptology — study of epilepsy by means of noninvasive location of epileptic focuses and determination of lateralization of speech center before the brain surgery.

Pediatrics neurology — study of corticospinal tract state of children suffering from cerebral palsy.

Pulmonology — stimulation of phrenic nerve for study of diaphragm response.

Transcranial magnetic stimulation.
 
Study of root conduction time.
 
Motor response variability.


 

Neuro-MS Delivery Set

  • Magnetic stimulator electronic unit
  • Big ring coil (150 mm)
  • Small ring coil (100 mm)
  • Figure-of-eight coil
  • Technical manual
  • Registration certificate

Big ring coil Small ring coil Figure-of-eight coil

Neuro-MS Specifications

Magnetic Stimulation Parameters  
Magnetic induction amplitude (depends on coil) 0 ÷ 2.2 Tl
Pulse shape biphase
Pulse duration 250 μs
Stimulation frequency 0.1 ÷ 30 Hz
Stimulation frequency at maximal induction 5 Hz
Stimulation train duration 0.5 ÷ 10 s
Pauses between trains 0.5 ÷ 30 s
Session time 0.5 ÷ 30 min
General Specifications and Parameters  
Supply voltage 220±22 V, 50/60 Hz
Power consumption not more than 1000 W
Electronic unit dimensions 512×310×180 mm
Electronic unit weight not more than 15 kg
Safety BF type

Modes of Operation

  • Autonomous single pulse
  • Autonomous repetitive stimulation
  • Under control of digital neurophysiological systems Neuro-MEP-4, Neuro-MEP-8, Neuro-MEP-Micro, Neuro-EMG, Neuro-EMG-Micro, Neuron-Spectrum-4/EP, Neuron-Spectrum-5 manufactured by Neurosoft Ltd.
  • Under control of digital EMG systems produced by other manufacturers*

* To synchronize the operation with the external equipment, use the “Start” input signal (from electrical stimulators of digital EMG systems) and “Synchronization” output signal.